0102030405
Container Energy Storage With 360KW EV Charing Stations System
PRODUCT INTRODUCTION
Smart BESS EV Charging Station
Applied in intercity expressway and expressway to achieve energy integration and economical transportation.
It can be applied to bus charging stations or public charging stations in the city to achieve efficient utilization and increase added value by using idle areas.
It can be applied in other fields, such as idle roof, parking shed, power distribution capacity expansion of charging station, etc., which can be solved through integration of multiple power sources.
FEATURES
Charging Interface
Are there charging guns other than the national standard?
There are European, American, Japanese, and Chinese standard.

Solution Features
●Economical and Efficient. Photovoltaic installed on the parking shed is used to supplement the power source, to achieve peak and valley arbitrage, and to expand distribution capacity of charging stations.
●Multi-Functionalization. The system functions integrate the power generation of the photovoltaic system, the storage power of the energy storage system and the power consumption of the charging station, and operate flexibly in a variety of modes. System design according to local conditions.
●Intelligentize. The EV charging station receives the dispatching of different control layers such as local distribution dispatching and centralization micro–grid.
●Emergency power supply function. The energy storage system can provide emergency power supply for important loads such as EV chargers.
●Economical and Efficient. Photovoltaic installed on the parking shed is used to supplement the power source, to achieve peak and valley arbitrage, and to expand distribution capacity of charging stations.
●Multi-Functionalization. The system functions integrate the power generation of the photovoltaic system, the storage power of the energy storage system and the power consumption of the charging station, and operate flexibly in a variety of modes. System design according to local conditions.
●Intelligentize. The EV charging station receives the dispatching of different control layers such as local distribution dispatching and centralization micro–grid.
●Emergency power supply function. The energy storage system can provide emergency power supply for important loads such as EV chargers.
Operation Mode
●Peak hours during the day
During peak hours of the day, photovoltaic power generation is used by charging stations, and excess power is stored in the energy storage system or fed back to the grid. When the photovoltaic power is insufficient, the energy storage system will discharge to supplement the distribution capacity of the charging station.
It can be mainly used to improve the income of new energy power generation, delay the cost investment of power distribution and capacity expansion, and obtain peak-valley arbitrage.
●Valley hours during the night
●Valley hours during the night
In the valley hours during the night, the photovoltaic system stops generating electricity, and at the same time, it is charged from the municipal power station to the charging station and energy storage system.
PRODUCT SPECIFICATIONS

| Model | 1MWh-20 feet | 2MWh-20 feet | 3MWh-40 feet |
| System Capacity (Mwh) | 1 | 2 | 3 |
| Platform Voltage (V) | 716.8 | 768 | 768 |
| Battery Module Model | 51.2V 280Ah | 51.2V 280Ah | 51.2V 280Ah |
| Charge And Discharge Rate | 0.5C | 0.5C | 0.5C |
| Cooling Method | Air cooling/Iquid-cooled | Air cooling/Iquid-cooled | Air cooling/Iquid-cooled |
| Fire Extinguishing System | Yes | Yes | Yes |
| Dimension (Mm) | 6096*3438*2896 | 6096*3438*2896 | 12191*2438*2896 |
| Weight (Ton) | 18 | 24 | 40 |
| Working Temperture (°C) | -20~60 | -20~60 | -20~60 |
| Communication Protocols | 485、CAN | 485、CAN | 485、CAN |
|
DC Charging Pile Parameter
|
|||||
|
Model
|
CFS400087A
|
CFS400173A
|
CFS400230A
|
CFS400260A
|
|
|
Details
|
Rated power
|
160KW
|
180KW
|
240KW
|
360KW
|
|
Charging equipment
|
Range of output current
|
0-200A
|
0-250A
|
||
|
Dimension
|
650*620*1700mm
|
||||
|
Type of cable input
|
Input from bottom input and output from top
|
||||
|
Installation type
|
Floor-standing
|
||||
|
Input voltage
|
AC400V±15%
|
||||
|
Input frequency
|
50~60Hz
|
||||
|
Output voltage
|
200V-1000V
|
||||
|
User interface
|
7 inches LCD colorful touching screen
|
||||
|
Cable length
|
5m
|
||||
|
Measure accuracy
|
0.5 grade
|
||||
|
Electrical parameters
|
Protection limit
|
≥110%
|
|||
|
Stabilizing voltage accuracy
|
≤±0.5%
|
||||
|
Stabilizing current accuracy
|
≤±1%
|
||||
|
Ripple factor
|
≤±0.5%
|
||||
|
Efficiency
|
≥94.5%
|
||||
|
Power factor
|
≥0.99 ( over 50% load)
|
||||
|
THD
|
≤5% ( over 50% load)
|
||||
|
Function setting
|
Human-device interface
|
7 inches LCD colorful touching screen
|
|||
|
Charging mode
|
Automatic charging/Electricity volume charging/Amount charging//Timing charging
|
||||
|
Payment type
|
Payment by card swiping/APP/QR Code
|
||||
|
Communication interface
|
Ethernet
|
||||
|
Security setting
|
Standard
|
IEC61851 、ISO15118/DIN70121 、IEC62196 、SAE-J1772
|
|||
|
Safety function
|
Temperature detection of charging gun/ Over-voltage protection/Under voltage protection/Over load protection/Short circuit protection/Grounding protection/Over temperature protection/Low temperature protection/Insulation detection protection/Polarity reverse protection/Lightning protection/Emergency stop protection/Leakage protection
|
||||
|
Environmental parameters
|
Working temperature
|
-40℃~+70℃
|
|||
|
Working Humidity
|
5%~95% no frosting
|
||||
|
Protection level
|
IP54
|
||||
|
Cooling type
|
Forced fan cooling
|
||||
|
Noise control
|
≤60dB
|
||||
|
MTBF
|
100,000 hours
|
||||

Wall-Mounted Battery
Stackable Battery
Rack-Mounted Battery
All In One Inverter Battery
Energy Storage Cabinet
Energy Storage Container
Solar Panel
Solar Inverter